Treatment method when the air shower is faulty

Common fault handling of stainless steel air shower :

First, the power switch. Usually there are three places in the stainless steel air shower to cut off the power:

1. The power switch of the outer box;

2. The control panel of the inner box;

3. On both sides of the outer box (the power switch here can prevent the power supply from being cut off in an emergency, effectively improving the personal safety of the staff). When the power indicator does not work, do not check the above three stainless steel air shower power supply.

Second, the stainless steel air shower chamber fan does not work. When the air shower is not working, check the emergency switch of the outdoor shower box for the first time. If it is determined to be cut off, gently press it with your hand and turn it to the right to release the hand.

3. The stainless steel air shower chamber fan is reversed or the wind speed is very small. Please check whether the 380V three-phase four-wire line is reversed. Generally, the air shower room manufacturer will install a special electrician to connect the line when the factory is installed. Airshower line source, the light will cause air shower fan does not work or reversal Airshower reduction of wind speed, in serious cases will be burned circuit boards throughout the air shower room; recommended Airshower companies do not lightly go Replace the wiring, if the production needs to be determined to move, please ask the air shower room manufacturer to solve.

Fourth, the stainless steel air shower does not blow, in addition to the above three points, it is also necessary to check whether the emergency stop button inside the air shower box is pressed. If the emergency stop button is color, the air shower will not blow. ; Press the emergency stop button again to work properly.

5. When the stainless steel air shower room cannot automatically sense the blowing, please check the light sensing system in the lower right corner of the air shower indoor box to see if the light sensing device is installed correctly. If the light sense is positive and the light is normal, it can be automatically sensed. Blowing.

6. When the stainless steel air shower is used for a period of time, if the wind speed is very low, please check if the initial and high-efficiency filters of the air shower are excessively dusty. If so, please replace the Filter. (Air filter room primary effect filter is usually replaced within 1-6 months, air shower room high efficiency filter is generally replaced within 6-12 months)